Maintain long-term voltage stability performance
Key points for correct installation
Install in the direction of the arrow to ensure the correct flow of the medium
Install a filter in front of the valve to protect the valve core and seals
Avoid severe vibrations or sudden temperature changes in the installation location
Leave enough maintenance space for easy adjustment and maintenance
Troubleshooting Guide
Unstable pressure: Check if the diaphragm is damaged and if the spring is malfunctioning
Slow response adjustment: Check if the valve core is stuck and if the filter is clogged
Continuous low outlet pressure: Check if the inlet pressure is sufficient and if the pipeline in front of the valve is blocked
Abnormal leakage: Check if the seals are worn and if the fasteners are loose